Product selector

Series
CS 59Pa
Concept System 59 Parallel door
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent1400 mm
Min. Visible width frame-vent: inward opening139 mm
Wind load resistanceC
Energy levelNon Insulated

Series
SlimLine 38
SlimLine 38 door
- Well balanced price-quality-feature mix
Max. height vent2500 mm
Air tightness max. test pressure3 (600 Pa)
Acoustic performanceRw(C;Ctr) = 38(-1;-4) dB -
Rw(C;Ctr) = 45 (-1;-5) dB
Max. width vent1250 mm
Water tightness4A (150 Pa)
Thermal insulation (Uf)1,9 W/m²K
Min. Visible width frame-vent: inward opening101.5 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
ES 45Pa
Eco System 45 'Parallel' door
Max. height vent2400 mm
Air tightness max. test pressure4 (600 Pa)
Max. width vent1400 mm
Water tightness7A (300 Pa)
Min. Visible width frame-vent: inward opening115 mm
Wind load resistanceC2 (800 Pa)
Energy levelNon Insulated

Series
MasterLine 8
MasterLine 8 doors
- Excellent thermal performances
- Highly competitive price-quality ratio
- Wide field of applicability
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 43(-1;-4) dB
Max. Glass thickness vent58 mm
Max. width vent1400 mm
Water tightness7A (300 Pa)
Thermal insulation (Uf)153mm: HI 2,2 / HI+ 1,4 W/m²K
178,5mm: HI+ 1,3 W/m²K
Min. Visible width frame-vent: inward opening153 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelPassive

Series
CS 77
Concept System 77 door
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 42(-1;-4) dB
Max. Glass thickness vent52 mm
Max. width vent1400 mm
Water tightness7A (300 Pa)
Thermal insulation (Uf)150mm: 2,1 W/m²K
Min. Visible width frame-vent: inward opening150 mm
Wind load resistanceC2 (800 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh

Series
CS 68
Concept System 68 door
- Well balanced price-quality-feature mix
- Minimal build-in depth for doors
- Reduced visible height for fixed windows and opening windows
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 37(-1;-4) dB -
Rw(C;Ctr) = 44(-2;-5) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Min. Visible width frame-vent: inward opening150 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh

Series
ES 50
Eco System 50 door
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 40(-2;-4) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Thermal insulation (Uf)3,2 W/m²K
Min. Visible width frame-vent: inward opening146 mm
Wind load resistanceC2 (800 Pa)
Energy levelHigh

Series
CS 59
Concept System 59 door
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for doors
Max. height vent3000 mm
Air tightness max. test pressure2 (300 Pa)
Acoustic performanceRw(C;Ctr) = 40(-2;-4) dB
Max. width vent1400 mm
Water tightness4A (150 Pa)
Min. Visible width frame-vent: inward opening149 mm
Wind load resistanceC
Energy levelMedium

Series
MasterLine 10
MasterLine 10 windows
- Best value for money amongst passive systems
- Wide range of solutions
- Design variants Renaissance and Deco available
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceTuTi: Rw(C;Ctr) = 46(-1;-4) dB
DC: Rw(C;Ctr) = 44(-2;-4) dB
Max. Glass thickness vent88 mm
Max. width vent1200 mm
Water tightnessE900 (900 Pa)
Thermal insulation (Uf)119mm: 0,90 W/m²K
Min. Visible width frame-vent: inward opening104 mm
Wind load resistanceC5 (2000 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelPassive

Series
CS 59
Concept System 59 window
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for fixed windows and opening windows
Max. height vent2400 mm
Air tightness max. test pressure4 (600 Pa)
Max. Glass thickness vent35 mm
Max. width vent1400 mm
Water tightness9A (600 Pa)
Min. Visible width frame-vent: inward opening89 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceWK2
Energy levelMedium

Series
MasterLine 8
MasterLine 8 window
- High air, wind & water tightness performances
- Excellent thermal values
- Increased productivity
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceTuTi: Rw(C;Ctr) = 46(0;-3) dB
DC: Rw(C;Ctr) = 44(-2;-4) dB
Max. Glass thickness vent68 mm
Max. width vent1200 mm
Water tightnessE900 (900 Pa)
Thermal insulation (Uf)119mm: St. 1,9 / HI 1,6 / HI+1,2 W/m²K
Min. Visible width frame-vent: inward opening97 mm
Wind load resistanceC5 (2000 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelPassive

Series
CS 59Pa
Concept System 59 'Parallel' window
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for fixed windows and opening windows
Max. height vent2400 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 44(-2;-4) dB
Max. Glass thickness vent35 mm
Max. width vent1400 mm
Water tightnessE750 (750 Pa)
Min. Visible width frame-vent: inward opening85 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceWK2
Energy levelNon Insulated

Series
ES 45Pa
Eco System 45 'Parallel' window
Max. height vent2000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 41(-1;-5) dB
Max. Glass thickness vent40 mm
Max. width vent1000 mm
Water tightness9A (600 Pa)
Min. Visible width frame-vent: inward opening84 mm
Wind load resistanceC3 (1200 Pa)
Energy levelNon Insulated

Series
SlimLine 38
SlimLine 38 window
- 40mm Thermal break on frame 32mm thermal break on vent
- 10mm Frame-vent rebate
- 13.5mm glass rebate
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 45(-1
-5) dB
-5) dB
Max. Glass thickness vent55 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,9 W/m²K
Min. Visible width frame-vent: inward opening67 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
SlimLine 68
SlimLine 68 window
- Ultra slim sightlines
- Optimal daylight access
Max. height vent1500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 47(-2;-7) dB
Max. Glass thickness vent43 mm
Max. width vent1200 mm
Water tightnessE1200 (1200 Pa)
Thermal insulation (Uf)Uw: 1,4 W/m²K
Wind load resistanceExxx (>2000 Pa)
Burglar resistancePAS 24
Energy levelHigh

Series
CS 77
Concept System 77 window
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for fixed windows and opening windows
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 42(-2; -4) dB
Max. Glass thickness vent63 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Min. Visible width frame-vent: inward opening89 mm
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh

Series
CS 68
Concept System 68 window
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Compatible with the Ventalis ventilation unit
Max. height vent2800 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 43(-2;-6) dB
Max. Glass thickness vent54 mm
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)2,5 W/m²K
Min. Visible width frame-vent: inward opening89 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh

Series
ES 50
Eco System 50 window
- Well balanced price-quality-feature mix
- Minimal build-in depth for insulated system
- Reduced visible height for fixed windows and opening windows
Max. height vent2200 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 38(-1;-3) dB
Max. Glass thickness vent32 mm
Max. width vent800 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)2,3 W/m²K
Min. Visible width frame-vent: inward opening86 mm
Wind load resistanceC4 (1600 Pa)
Burglar resistanceWK2
Energy levelHigh

Series
Hi-Finity
Hi-Finity
- Ultimate design freedom, matching each project requirement
- Floor-to-ceiling and wall-to-wall fully concealed profiles
- Elegant lines and an unobstructed view
Max. height vent4000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 46(-1;-3) dB
Max. width vent3500 mm
Water tightnessE750 (750 Pa)
Thermal insulation (Uf)1,4 W/m²K
Wind load resistanceC5 (2000 Pa)
Burglar resistanceRC2/WK2
Energy levelPassive

Series
SlimPatio 68
SlimPatio 68 sliding window
- Panoramic view with 34mm sight-lines
- Hi-Finity look and feel
- Flush design, flat view and concealed frame
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 40(-2;-4) dB
Max. width vent2300 mm
Water tightness8A (450 Pa)
Thermal insulation (Uf)2,4 W/m²K
Wind load resistanceB5 (2000 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
CP 155 (-LS)
Concept Patio 155 (-Lift Slide)
- A high end complete sliding door solution which makes the combination of high insulation and large dimensions possible
- Based on the exquisite know how of Reynaers regarding sliding doors
- Fabrication and logistical ease; minimal number of profiles, compatible with CS 77 and MasterLine 8
Max. height vent3500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 42(-1;-3) dB
Max. width vent2700 mm
Water tightnessE900 (900 Pa)
Thermal insulation (Uf)1,07 W/m²K
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
CP 130 (-LS)
Concept Patio 130 (-Lift Slide)
- The complete sliding door solution hich offers a large choice in designs and functionalities
- Based on the exquisite know how of Reynaers regarding sliding doors
- Fabrication and logistical ease; minimal number of profiles, compatibel with CS 68
Max. height vent2700 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 39(-1;-3) dB
Max. width vent2700 mm
Water tightnessE750 (750 Pa)
Thermal insulation (Uf)2,35 W/m²K
Wind load resistanceB5 (2000 Pa)
Burglar resistanceRC2/WK2
Energy levelHigh

Series
CP 68
Concept Patio 68
- Performance and elegance; ultimate in light with maximum comfort and safety.
- Large variety of configurations
- Compatible with other Reynaers systems
Max. height vent2500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 38(-2;-4) dB
Max. width vent1500 mm
Water tightness7B (300 Pa)
Thermal insulation (Uf)2,5 W/m²K
Wind load resistanceC4 (1600 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
CF 77
Concept Folding 77
- Standalone folding system
- Large variety of configurations (from 2 to 8 vents)
- Symmetrical design: In- and outward opening with same profiles & accessories
Max. height vent3000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 34(-2;-5) dB -
Rw(C;Ctr) = 45(-1;-5) dB
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)2,25 W/m²K
Wind load resistanceC3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
CF 68
Concept Folding 68
- Wide range of configurations up to 8 vents
- High AWW performance and burglar resistance class RC2 with 2 point locking gear to provide maximum comfort and security
- Compatible with other Reynaers systems
Max. height vent2500 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 35(-1;-4) dB -
Rw(C;Ctr) = 40(-2;-4) dB
Max. width vent1200 mm
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Wind load resistanceB3 (1200 Pa)
Burglar resistanceRC2/WK2
Energy levelSuper High

Series
CP 45Pa
Concept Patio 45 Parallel
- Functional and softline design
- Choice between stainless steel or aluminium rail
- Several new configurations like central sliding, build in sliding
Max. height vent2300 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 30(-1;-3) dB
Max. width vent1300 mm
Water tightness7B (300 Pa)
Wind load resistanceC4 (1600 Pa)
Energy levelNon Insulated

Series
CP 50
Concept Patio 50
- Functional and softline design
- Choice between stainless steel or aluminium rail
- Several new configurations like central sliding, build-in slididng
Max. height vent2500 mm
Air tightness max. test pressure3 (600 Pa)
Acoustic performanceRw(C;Ctr) = 33(-1;-2) dB
Max. width vent3500 mm
Water tightness7B (300 Pa)
Thermal insulation (Uf)3,4 W/m²K
Wind load resistanceA3
Energy levelHigh

Series
CW 50
Concept Wall 50
- High performance towards Air, wind and water testing
- High insulative compared with comparable sections
- High maximal dimensions, possible to build large elements.
Air tightness max. test pressure1200
Acoustic performanceRw(C;Ctr) = 60(-2;-6) dB
Water tightness1200
Thermal insulation (Uf)0,8 W/m²K
Burglar resistanceRC2/WK2 - RC3/WK3
Energy levelHigh

Series
CW 60
Concept Wall 60
- High performance towards air, wind and water testing
- High insulative compared with comparable sections
- High maximal dimensions, possible to build large elements
Max. height vent2000 mm
Air tightness max. test pressure4 (600 Pa)
Acoustic performanceRw(C;Ctr) = 47(-2;-5) dB
Max. width vent2500 mm
Water tightness1200
Wind load resistanceExxx (>2000 Pa)
Energy levelHigh

Series
CW 65-EF
Concept Wall 65 'Element Façade'
- Slim line design with a minimal joint between the glazing beads or glass panes
- High performance towards air, wind and water testing
- High insulative compared with comparable sections
Max. height vent3700 mm
Air tightness max. test pressureAE 700 (700 Pa)
Acoustic performanceRw(C;Ctr) = 37(-1;-3) dB
Max. width vent1600 mm
Water tightness1200
Thermal insulation (Uf)2,5 W/m²K
Energy levelHigh

Series
CW 86
Concept Wall 86
- Slim line design with a minimal joint between the glazing beads or glass panes
- High performance towards air, wind and water testing
- High insulative compared with comparable sections
Acoustic performanceRw(C;Ctr) = 41(-2;-5) dB
Water tightnessRE1050 (1050 Pa)
Thermal insulation (Uf)3,9 W/m²K
Wind load resistanceB5 (2000 Pa)
Energy levelHigh

Series
BS 100
Brise Soleil 100
- Watertight connection guiding the cables to the inside of the CW 60 system
- Connection to CW 50

Series
TR 200
Thermo Roof 200
Air tightness max. test pressure3 (600 Pa)
Water tightness9A (600 Pa)
Thermal insulation (Uf)1,8 W/m²K
Wind load resistanceC2 (800 Pa)

Series
Cintro
Cintro roof system
- The system is extremely suitable for aluminium arched spans
- The minimum radius is 400mm
- The flat shells give the roof a streamlined finish

Series
Ventalis
Ventalis
- Fully integrated solution
- Anchoring on top of the elements with Ventalis is identical as anchoring without Ventalis to guarantee severe building connection
- Large choice of applications, configuration and design modularity without limitation towards the needed airflow

Series
Ouvea
Air tightness max. test pressure3 (600 Pa)
Water tightness4B (150 Pa)
Wind load resistanceC5 (2000 Pa)

Series
Touch
Timeless and versatile
- Timeless and versatile
- Available for our complete range of opening types
- Available in 400+ RAL colours in matte, glossy, satin and coatex (textured), and with an anodised finish.
Burglar resistanceSKG 2

Series
Horizon
Contemporary renovation
- Contemporary renovation
- Available in 400+ RAL colours in matte, glossy, satin and coatex (textured), and with an anodised finish.
Burglar resistanceRC2/WK2 - SKG 2

Series
Purity
Exclusive and elegant design
- Unique design
- PURA, anti-bacterial and fully recyclable material
Burglar resistanceRC2/WK2 - RC3/WK3 - SKG 2 - SKG 3