Performance

Energy

Thermal insulation - Uf
0.99 W/m²K
Thermal insulation - Uw
0.8 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23x1.48m (104mm sight line), 48mm glass

Comfort

Acoustics - Rw(C;Ctr)
TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB

Safety

Burglar resistance
RC2,RC3
* Note: Performances and properties may be different depending on the profile combinations

Properties

Sightlines

Min. frame width (inward opening)
60 mm
Min. vent width (inward opening)
37 mm
Min. frame-vent width (inward opening)
104 mm
Min. frame width (outward opening)
27 mm
Min. vent width (outward opening)
113 mm
Min. frame-vent width (outward opening)
140 mm
Depth frame
97 mm
Depth Vent
107 mm
Depth frame-vent
107 mm

Glazing

Rebate height
27 mm
Min. glass thickness - vent
30 mm
Max. glass thickness - vent
88 mm